Notify when current changes
In IoT scenarios, it is a very common scenario to trigger events when indicators change. This article will use current changes as an example to introduce eKuiper SQL rules.
Background
In this scenario, stream will continuously send the current current data in the form of a stream, as well as the timestamp to which the data belongs. In this document, we will use the sample input data as follows:
{
"current": 300,
"ts": 1,
"deviceId": 1
}
{
"current": 400,
"ts": 2,
"deviceId": 2
}
{
"current": 200,
"ts": 3,
"deviceId": 1
}
{
"current": 200,
"ts": 4,
"deviceId": 2
}
{
"current": 500,
"ts": 5,
"deviceId": 1
}
{
"current": 200,
"ts": 6,
"deviceId": 2
}
{
"current": 400,
"ts": 7,
"deviceId": 1
}
{
"current": 600,
"ts": 8,
"deviceId": 2
}
Trigger When Changed Value Pass Threshold
In IoT applications, users often need to monitor whether sensor values exceed a certain threshold, thereby triggering alarms or other actions. Simply comparing the current value with the threshold may lead to continuous triggering of alarms. Therefore, what users might actually need is to trigger an alarm when the value changes from not exceeding the threshold to exceeding it, which implies a process of judging the change. Let's check how eKuiper can help to fulfill this requirement.
1. Changed current value exceeds 300
select current, ts
from demo
where current > 300 and lag(current) <= 300;
This rule will record the last data of the current, and then compare it with the current data. Once the conditions are met, the event will be triggered.
{"current":400,"ts":2}
{
"current": 500,
"ts": 5
}
{
"current": 400,
"ts": 7
}
Notice that, this rule will check all deviceIds all together. If you need to separate devices, checkout the next scenario.
2. Changed current value of a deviceId exceeds 300
select current, deviceId, ts
from demo
where current > 300 and lag(current) over (partition by deviceId) < 300;
This rule will record lag value partition by device. Thus the output will be:
{
"current": 500,
"ts": 5,
"deviceId": 1
}
{
"current": 600,
"ts": 8,
"deviceId": 2
}
Although the input stream mixes data from multiple devices, we can still calculate the lag value separately.
3. Changed value of a specific device
If users only care about a specific device, we can use OVER when clause to only calculate state of concerned device.
select current, deviceId, ts
from demo
where current > 300 and deviceId = 1 and lag(current) over (when deviceId = 1) < 300;
The output will be:
{
"current": 500,
"ts": 5,
"deviceId": 1
}
In this rule, the where clause has condition deviceId = 1
to specify the deviceId. And in the lag function, over when clause limits the lag value to only record when deviceId=1
. This will only capture changes of device 1, regardless of other devices in the same stream.
Besides lag
function, other analytic functions like had_changed also supports the OVER clause to limit the state dimension. Check analytic functions for detail.
Trigger When Passing Threshold for Some Time
select current from demo group by SLIDINGWINDOW(ss,0,10) over (when current > 200) having min(current) > 200;
This rule will open a window when receiving current data above 200A. If the smallest data in the window is also greater than 200A, the requirements are met and the event is output.
{"current":100,"ts":1}
{"current":300,"ts":2}
{"current":300,"ts":3}
{"current":300,"ts":4}
{"current":300,"ts":5}
{"current":300,"ts":6}
{"current":300,"ts":7}
{"current":300,"ts":8}
{"current":300,"ts":9}
{"current":300,"ts":10}
{
"current": 300,
"ts": 11
} Output Event